OSCILLOSCOPE MODEL
Overview

The VSM Oscilloscope is supplied as standard with all versions of ProSPICE and models a basic four beam unit and is specified as follows:
- Live probing and probe switching during simulation.
- Four channel or X-Y operation.
- Channel gain from 20V/div to 2mV/div with 2.5x accurate set-up.
- Timebase from 200ms/div to 0.5us/div with 2.5x accurate set-up.
- Automatic voltage level triggering locked to either channel.
- AC or DC coupled inputs.
- A+B and C+D channel modes.
- Invert button for each channel.
- Mouse zoom in and out.
- Cursors measurement.
- One-shot mode with zoom in and out possibility.
- Printing.
- Colour change for each channel.
System Scope vs Placed Scope
A system scope is provided directly on the animation control panel as the default measuring device during a simulation
![]()
The system scope window opens docked at the bottom of the editor and probing takes place live during simulation.
Alternatively, you can place and wire the scope instrument to lines of interest directly on the schematic.

In practise, most people will simply use the system scope as it is simpler and more convenient to work with. However, there are three reasons why you might want to place and wire the scope instrument instead:
- You need to probe more than 4 lines of interest. Each scope is 4-channel and so if you need > 4 channels at one time you will need to place and connect scope instruments.
- The configuration of the live probing is stored in the workspace file, not the project. So if you want a sample/example where the scope is pre-connected it needs to be wired. Sharing a project.
- You prefer to have everything visually on the schematic at design time.
When the simulation is running the look and behaviour is (almost) identical. For the purposes of this document we will assume you are using the system scope and will then note differences for a placed scope where needed.
Live Probing
Live probing works by connecting or moving a scope probe to a line of interest during a simulation.
To connect a live probe
- Start the simulation
- Open the system scope
- Click on the probe icon for a channel. The probe will follow the mouse on the schematic.
- Click on the wire of interest that you want to probe.

The probe icon will turn green if connected to an analog line and blue if connected to a digital line. It will remain uncoloured if not connected. In the case of channels which have been hard wired with a placed instrument the probe icon will be coloured and you cannot place a probe on that channel (it's already connected !).
You cannot attach a live probe to a bus.
To move a live probe
- Click on the probe icon for the channel in question. The mouse will move to the probe location and pick up the probe.
- Move the mouse to the new line of interest and left click to place it there.

Probes can be deleted from the context menu when the simulation is stopped in the same way as other devices. You can simply move the probe to a location in free space or turn the scope channel off should you want to declutter your scope screen during a simulation run.
Probe locations will persist across simulation runs and Proteus sessions. The probe information is stored in the workplace file (not the project file) so probes will be lost if the project file is moved or shared. They can of course then simply be added again or you can place and wire the scope instrument to fix the line connections to the instrument.
Using the Oscilloscope
To display analog waveforms
- Press play to start the simulation.
- Click on the system scope to open it.
- Click on the live probe icon for a channel and then drop the probe onto the line of interest.
OR
- Pick the OSCILLOSCOPE object by selecting the Meter icon in ISIS and then selecting the Oscilloscope from the Object Selector.
- Place one on the schematic and wire its inputs to the signals you want to record.
- Start an interactive simulation by pressing the play button on the Animation Control Panel. The oscilloscope window should appear.
THEN
- Set the timebase dial in Horizontal section to a suitable value for the circuit. You will need to think about the waveform frequencies present in your circuit, and convert these to cycle times by taking their reciprocal.
- If displaying signals with a DC offset, select AC mode on either or every input channel as appropriate. You can also turn off unused channels by choosing OFF mode.
- Adjust the voltage and position dials in Channel A...Channel D sections so that the waveforms are of a suitable size and position. If a waveform consists of a small AC signal on top of a large DC voltage you may need to connect a capacitor between the test point and the oscilloscope, as the position controls can compensate for only a certain amount of DC.
- Decide which channel you want to trigger off, using the Source slider from Trigger section.
- Choose the required part of waveform by using the slider from Trigger section It will lock to rising slopes if the slider points up, and falling slopes if it points down.
Modes of Operation
The oscilloscope can operate in the following modes:
- Auto - the Auto button LED is lit in this mode.
- One-Shot - the Auto button LED is off. In this mode the One-Shot LED will be lit if capturing is in progress and off after the finishing capture.
- X-Y mode - the Source slider form Horizontal section positioned in selected X channel.
Triggering
The VSM oscilloscope provides an automatic triggering mechanism which enables it synchronize the timebase to the incoming waveform.
- The Source slider in the Trigger section can select which input channel is used for triggering.
- The AC/DC slider is used for selection of absolute or channel-linked trigger offset.
- The Level dial used for trigger offset value setup.
- The Edge selection slider is used for choosing rising or falling edge of waveform.
Input Coupling
Each input channel can either be directly coupled (DC coupling) or coupled through a simulated capacitance (AC coupling). The latter mode is useful for displaying signals that carry a small AC signal on top of a much larger DC bias voltage.
The inputs may also be temporarily grounded by selecting the GND slider position that can be useful when aligning them to the graticule prior to taking measurements. Inputs may be switched off by moving the slider into the OFF position. Two inputs can be summed by using A+B or C+D buttons. Using Invert button each channel may be inverted.
Taking Measurements
Measuring of voltage, difference of voltages, time difference between trigger point and current of between any two points can be performed by using the cursors. To use this feature select the Cursors button. To set absolute cursor into screen just move the mouse to appropriate position and press left mouse button. To set different cursor, move mouse while left button is depressed. Cursors can be moved by mouse (while mouse is over any lines of the cursor) as well as deleted using the context menu – items “Delete Cursor” or “Clear All Cursors”.

Deleting a Cursor from the Oscilloscope
Printing
Current waveform displayed on the screen can be printed using context menu item “Print…”.
Colours
Colours of each channel can be changed in “Colours Setup” dialog which one can be opened by choosing context menu item “Colours Setup…”.

You can also change the Colours by right clicking on the Oscilloscope and selecting Setup